The core steps to fix stuck or looping Diagrid agent workflows are validating persisted state, isolating issues via replay tools, adjusting workflow definitions, and clearing stuck state entries. Inspect persisted state for unprocessed external calls or unresolved branching logic, use Diagrid’s replay tools to pinpoint loop or block locations, then refine definitions or clear stale state entries. Note that containing stuck runs does not prevent future incidents, so pair fixes with proactive alerting.